Tipe | Low Ambient Suhu Sumber Udara Pompa Panas | Padumukan Bahan | Plastik, Lambaran galvanis |
Panyimpenan / Tankless | Sirkulasi Pemanasan | Pamasangan | Freestanding, témbok dipasang / Freestanding |
Paké | Cai Panas / Pemanasan Lantai / Fancoil Pemanasan Sareng Penyejukan | Pemanasan Kapasitas | 4,5-20KW |
Refrigerant | R410a / R417a / R407c / R22 / R134a | Kompresor | Copeland, Copeland Gulung Compressor |
Voltaseu | 220V〜lnverter,3800VAC/50Hz | Kakuatan suplai | 50/60Hz |
Fungsi | Pemanasan Imah, Pemanasan Spasi & Cai Panas, Pemanasan Cai Kolam, penyejukan sareng DHW | Pulisi | 4.10-4.13 |
Panas Penukar | Shell Panas Exchanger | Évaporator | Emas Hidrofilik Aluminium Fin |
Gawé Ambient Suhu | Minus -25C- 45C | Kompresor Tipe | Copeland Gulung Compressor |
Warna | Bodas, kulawu | Aplikasi | Jacuzzi Spa / Kolam Renang, Hotél, Komérsial sareng Industri |
Daya Input | 2,8-30KW | Cahaya Luhur | hawa tiis pompa panas, inverter sumber hawa pompa panas |
Suhu ambient anu béda bakal mangaruhan pangaruh jasa sareng umur jasa unit pompa panas.Dina hawa ambient low di kalér, perlu ngagunakeun pompa panas suhu ultra-low husus pikeun hawa ambient low pikeun mastikeun mimiti normal jeung operasi nu numput panas .. Solarshine ultra-low suhu sumber hawa pompa panas adopts a husus kompresor pompa panas, anu ogé tiasa beroperasi sacara stabil, panas éfisién sareng manjangkeun umur jasa unit dina kaayaan lingkungan hawa ultra-low ka -25 ℃.
Modél | KDR-03 | KDR-05S | KDR-05-G | KDR-07-G | KDR-10-G | KDR-15 | KDR-20 | KDR-25 | |
HP | 3 hp | 5 hp | 5 hp | 7 hp | 10 HP | 15 HP | 20 HP | 25 HP | |
Sasayogian tanaga | 220V / 380V | 220V | 380V | 380V | 380V | 380V | 380V | 380V | |
kakuatan input | 2.8 | 4.2 | 4.7 | 5.2 | 9.2 | 13 | 18.5 | 20.5 | |
Output kakuatan pemanasan dina tem ambient béda. | (20℃) | 10.8 | 16.2 | 18 | 20 | 35.4 | 50 | 71.2 | 78.9 |
(6/7℃) | 9 | 13.7 | 15.3 | 16.9 | 30 | 42.3 | 60 | 66.6 | |
(-6/7℃) | 6.9 | 10.3 | 11.5 | 12.7 | 22.5 | 319 | 453 | 50.2 | |
(-15℃) | 5.9 | 8.8 | 9.9 | 10.9 | 19.3 | 273 | 38.9 | 43 | |
(-20℃) | 5.2 | 7.8 | 8.7 | 9.6 | 17 | 24 | 34.2 | 37.9 | |
Kaluaran kakuatan cooling | 8.0 | 12.0 | 13.4 | 14.8 | 26.2 | 37.1 | 52.7 | 68.4 | |
arah outlet kipas | Samping | Samping | Samping | Samping | Samping | Samping | Puncak | Puncak | |
V\faler sambungan | DN25 | ON25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | |
Laju Cairan (M3/H) | 2-3 | 4-5 | 5-6 | 5-7 | 7-10 | 12-15 | 15-20 | 20-25 | |
Diménsi -sion | (MM) | 1152 | 1190 | 1190 | 1190 | 1350 | 1350 | 1800 | 1800 |
(MM) | 422 | 425 | 425 | 425 | 645 | 645 | 1100 | 1100 | |
(MM) | 768 | 1240 | 1240 | 1240 | 1845 | 184S | 2100 | 2100 | |
Beurat (kg) | 130 | 180 | 160 | 220 | 310 | 355 | 630 | 780 |
Naha sumber hawa pompa panas tiasa dianggo sacara stabil dina - 25℃?
Seueur anu salah paham ngeunaan pompa panas sumber hawa utamina museurkeun kana naha éta tiasa beroperasi sacara stabil dina suhu ambien anu handap.,utamana sabab masih tetep dina pamahaman saméméhna maranéhanana pompa panas biasa sarta kurangna pamahaman cukup ngeunaan pompa panas-suhu low.
Komponén inti anu nyababkeun bédana kinerja antara pompa panas suhu rendah sareng pompa panas biasa nyaéta compressor.Alesan naha pompa panas-suhu low bisa beroperasi normal dina suhu ambient handap pikeun ngajawab sababaraha masalah encountered ku pompa panas konvensional - kapasitas pemanasan teu cukup, cop lemah sareng operasi teu stabil disababkeun ku hawa évaporasi low, aliran nyeuseup low, rasio komprési badag. jeung suhu knalpot tinggi.
Anu kahiji nyaéta desain struktur internal.Profil ngagugulung tina compressor pompa panas-suhu lowisdirancang leuwih badag, nu hartina dina kaayaan suhu évaporasi handap, pompa panas-suhu low bisa ménta efisiensi kerja luhur jeung suhu évaporasi handap rentang kerja pikeun adaptasi jeung lingkungan gawé kalawan bédana hawa badag.