Tipe | Low Ambient Suhu Sumber Udara Pompa Panas | Bahan Perumahan | Plastik, Lambaran galvanis |
Panyimpenan / Tankless | Sirkulasi Pemanasan | Pamasangan | Freestanding, Tembok dipasang / Freestanding |
Paké | Cai Panas / Pemanasan Lantai / Fancoil Pemanasan Sareng Penyejukan | Kapasitas pemanasan | 4,5-20KW |
Refrigerant | R410a / R417a / R407c / R22 / R134a | Kompresor | Copeland, Copeland Gulung Compressor |
Voltaseu | 220V 〜lnverter, 3800VAC/50Hz | Sasayogian tanaga | 50/60Hz |
Fungsi | Pemanasan Imah, Pemanasan Spasi & Cai Panas, Pemanasan Cai Kolam, penyejukan sareng DHW | Pulisi | 4.10-4.13 |
Penukar Panas | Shell Panas Exchanger | Évaporator | Emas Hidrofilik Aluminium Fin |
Gawé Suhu Ambient | Minus -25C- 45C | Tipe Kompresor | Copeland Gulung Compressor |
Warna | Bodas, kulawu | Aplikasi | Jacuzzi Spa / Kolam Renang, Hotél, Komérsial sareng Industri |
Daya Input | 2,8-30KW | Cahaya Luhur | hawa tiis pompa panas, inverter sumber hawa pompa panas |
Naon prinsip kerja tina hawa ambient low sumber hawa pompa panas?
Unit pompa panas nyaéta sistem katutup diwangun ku evaporator, condenser, compressor jeung klep ékspansi, nu ngeusi jumlah luyu tina refrigerant.
Prinsip dasar operasi pompa panas dumasar kana prinsip siklus Carnot sabalikna: refrigerant cair mimiti nyerep panas dina hawa dina evaporator jeung evaporates pikeun ngabentuk uap (vaporization), sarta vaporization panas laten nyaéta panas pulih.Lajeng dikomprés kana-suhu luhur sarta gas-tekanan tinggi ku compressor jeung asup condenser ka condense kana cair (liquefaction) pikeun ngirim panas diserep kana cai kolam renang dipanaskeun diperlukeun, The refrigerant cair mulih deui ka klep ékspansi sanggeus depressurization na ékspansi ngaliwatan klep ékspansi, absorbs panas sarta evaporates pikeun ngalengkepan siklus a.Ku cara kieu, éta terus nyerep panas tina sumber-suhu lemah sareng kaluaran cai kolam renang anu dipanaskeun pikeun langsung ngahontal suhu anu parantos ditangtukeun.
Modél | KDR-03 | KDR-05S | KDR-05-G | KDR-07-G | KDR-10-G | KDR-15 | KDR-20 | KDR-25 | |
HP | 3 hp | 5 hp | 5 hp | 7 hp | 10 HP | 15 HP | 20 HP | 25 HP | |
Sasayogian tanaga | 220V / 380V | 220V | 380V | 380V | 380V | 380V | 380V | 380V | |
kakuatan input | 2.8 | 4.2 | 4.7 | 5.2 | 9.2 | 13 | 18.5 | 20.5 | |
Output kakuatan pemanasan dina tem ambient béda. | (20℃) | 10.8 | 16.2 | 18 | 20 | 35.4 | 50 | 71.2 | 78.9 |
(6/7℃) | 9 | 13.7 | 15.3 | 16.9 | 30 | 42.3 | 60 | 66.6 | |
(-6/7℃) | 6.9 | 10.3 | 11.5 | 12.7 | 22.5 | 319 | 453 | 50.2 | |
(-15℃) | 5.9 | 8.8 | 9.9 | 10.9 | 19.3 | 273 | 38.9 | 43 | |
(-20℃) | 5.2 | 7.8 | 8.7 | 9.6 | 17 | 24 | 34.2 | 37.9 | |
Kaluaran kakuatan cooling | 8.0 | 12.0 | 13.4 | 14.8 | 26.2 | 37.1 | 52.7 | 68.4 | |
arah outlet kipas | Samping | Samping | Samping | Samping | Samping | Samping | Puncak | Puncak | |
V\faler sambungan | DN25 | ON25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | |
Laju Cairan (M3/H) | 2-3 | 4-5 | 5-6 | 5-7 | 7-10 | 12-15 | 15-20 | 20-25 | |
Diménsi -sion | (MM) | 1152 | 1190 | 1190 | 1190 | 1350 | 1350 | 1800 | 1800 |
(MM) | 422 | 425 | 425 | 425 | 645 | 645 | 1100 | 1100 | |
(MM) | 768 | 1240 | 1240 | 1240 | 1845 | 184S | 2100 | 2100 | |
Beurat (kg) | 130 | 180 | 160 | 220 | 310 | 355 | 630 | 780 |
Dibandingkeun sareng pompa panas biasa, dina - 10 ℃ sareng suhu anu langkung handap, suhu évaporasi rendah teuing, nyababkeun évaporasi kirang, nyababkeun volume hawa compressor anu kirang, anu mangaruhan kondensasi sareng pelepasan panas.Hiji enthalpy suntik nambahan cabang nyambungkeun compressor nu ditambahkeun kana ultra low hawa ambient pompa panas.Lamun hawa balik compressor nu teu cukup, cabang enthalpy suntik ngaronjatna bakal nyieun nepi hawa pikeun compressor nu, jadi sékrési panas condenser bakal ngaronjat, jadi masih bisa ngahasilkeun panas normal dina suhu pisan low.